Product Code Product Name QTY Price ($AUD) Action
ACT050-10-F CurrentTransformer 0-50A/10VDC CurrentTransformer 0-50A/10VDC - AcuAMP single-phase AC current transducer, fixed core, 0-10, 0-20, or 0-50A jumper-selectable input ranges, 0-10 VDC output, UL 508 listed
$170.00
ACT200-10-F CurrentTransformer0-200A/10VDC CurrentTransformer0-200A/10VDC - AcuAMP single-phase AC current transducer, fixed core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 0-10 VDC output, UL 508 listed
$180.00
ACT050-10-S CurrentTransfSplit 0-50A/10VDC CurrentTransfSplit 0-50A/10VDC - AcuAMP single-phase AC current transducer, split core, 0-10, 0-20, or 0-50A jumper-selectable input ranges, 0-10 VDC output, UL 508 listed
$190.00
ACT200-10-S CurrentTransfSplit0-200A/10VDC CurrentTransfSplit0-200A/10VDC - AcuAMP single-phase AC current transducer, split core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 0-10 VDC output, UL 508 listed
$199.00
ACT005-42L-F CurrentTrans 0-5A/4-20ma CurrentTrans 0-5A/4-20ma - AcuAMP single-phase AC current transducer, fixed core, 0-2 or 0-5A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$145.00
ACT050-42L-F CurrentTrans 0-50A/4-20ma CurrentTrans 0-50A/4-20ma - AcuAMP single-phase AC current transducer, fixed core, 0-10, 0-20, or 0-50A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$150.00
ACT200-42L-F CurrentTrans 0-200A/4-20ma CurrentTrans 0-200A/4-20ma - AcuAMP single-phase AC current transducer, fixed core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$220.00
ACT750-42L-F AcuAMP AC 375,500,750 AcuAMP AC 375,500,750 - AcuAMP single-phase AC current transducer, fixed core, 0-375, 0-500, or 0-750A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$360.00
ACT2000-42L-F AcuAMP AC 1000,1333,2000 AcuAMP AC 1000,1333,2000 - AcuAMP single-phase AC current transducer, fixed core, 0-1000, 0-1333, or 0-2000A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$475.00
ACT005-42L-S CurrentTransSplit 0-5A/4-20ma CurrentTransSplit 0-5A/4-20ma - AcuAMP single-phase AC current transducer, split core, 0-2 or 0-5A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$199.00
ACT050-42L-S CurrentTransSplit 0-50A/4-20ma CurrentTransSplit 0-50A/4-20ma - AcuAMP single-phase AC current transducer, split core, 0-10, 0-20, or 0-50A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$215.00
ACT200-42L-S CurrentTransSplit0-200A/4-20ma CurrentTransSplit0-200A/4-20ma - AcuAMP single-phase AC current transducer, split core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$235.00
ACTR005-42L-F Single phase AC 0-2, 0-5 amp Single phase AC 0-2, 0-5 amp - AcuAMP single-phase AC current transducer, true RMS, fixed core, 0-2 or 0-5A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$275.00
ACTR050-42L-F Single phase AC 0-10,0-20,0-5 Single phase AC 0-10,0-20,0-5 - AcuAMP single-phase AC current transducer, true RMS, fixed core, 0-10, 0-20, or 0-50A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$250.00
ACTR200-42L-F Single ph AC 0-100,0-150,0-20 Single ph AC 0-100,0-150,0-20 - AcuAMP single-phase AC current transducer, true RMS, fixed core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$260.00
ACTR750-42L-F AcuAMP AC 375,500,750 AcuAMP AC 375,500,750 - AcuAMP single-phase AC current transducer, true RMS, fixed core, 0-375, 0-500, or 0-750A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$420.00
ACTR2000-42L-F AcuAMP AC 1000,1333,2000 AcuAMP AC 1000,1333,2000 - AcuAMP single-phase AC current transducer, true RMS, fixed core, 0-1000, 0-1333, or 0-2000A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$534.00
ACTR005-42L-S Single phase AC 0-2, 0-5 Single phase AC 0-2, 0-5 - AcuAMP single-phase AC current transducer, true RMS, split core, 0-2 or 0-5A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$310.00
ACTR050-42L-S Single phase AC 0-10,0-20,0-5 Single phase AC 0-10,0-20,0-5 - AcuAMP single-phase AC current transducer, true RMS, split core, 0-10, 0-20, or 0-50A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$315.00
ACTR200-42L-S Single ph AC 0-100,0-150,0-20 Single ph AC 0-100,0-150,0-20 - AcuAMP single-phase AC current transducer, true RMS, split core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 4-20mA output, UL 508 listed
$320.00
DCT100-42-24-F AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, fixed core, 0-50, 0-75, or 0-100A jumper-selectable input ranges, 24 VAC/DC powered, 4-20mA output, UL 508 listed
$235.00
DCT200-42-24-F AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, fixed core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 24 VAC/DC powered, 4-20mA output, UL 508 listed
$235.00
DCT100-42-24-S AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, split core, 0-50, 0-75, or 0-100A jumper-selectable input ranges, 24 VAC/DC powered, 4-20mA output, UL 508 listed
$310.00
DCT200-42-24-S AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, split core, 0-100, 0-150, or 0-200A jumper-selectable input ranges, 24 VAC/DC powered, 4-20mA output, UL 508 listed
$310.00
DCT400-42-24-S AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, split core, 0-200, 0-300, or 0-400A jumper-selectable input ranges, 24 VAC/DC powered, 4-20mA output, UL 508 listed
$310.00
DCT100-10B-24-S AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, split core, bi-directional 0-100A input range, 24 VAC/DC powered, bi-polar +/- 0-10 VDC output, UL 508 listed
$370.00
DCT200-10B-24-S AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, split core, bi-directional 0-200A input range, 24 VAC/DC powered, bi-polar +/- 0-10 VDC output, UL 508 listed
$370.00
DCT300-10B-24-S AcuAMP DC current transducer AcuAMP DC current transducer - AcuAMP DC current transducer, split core, bi-directional 0-300A input range, 24 VAC/DC powered, bi-polar +/- 0-10 VDC output, UL 508 listed
$370.00
ACS150-AE-F Single Ph AC 1.5-150 NO 0.2amp Single Ph AC 1.5-150 NO 0.2amp - AcuAMP single-phase AC adjustable current switch, fixed core, 1-150A trip range adjustment with 15-turn potentiometer, N.O., 0.15A @ 240 VAC/DC output, LED indication, UL … (read more)
$135.00
ACS150-CE-F Single Ph AC 1.5-150 NC 0.2amp Single Ph AC 1.5-150 NC 0.2amp - AcuAMP single-phase AC adjustable current switch, fixed core, 1-150A trip range adjustment with 15-turn potentiometer, N.C., 0.2A @ 240 VAC/DC output, LED indication, UL … (read more)
$135.00
ACS150-AE-S Single Ph AC 1-150 NO 0.2amp Single Ph AC 1-150 NO 0.2amp - AcuAMP single-phase AC adjustable current switch, split core, 1.75-150A trip range adjustment with 4-turn potentiometer, N.O., 0.15A @ 240 VAC/DC output, LED indication, … (read more)
$160.00
ACS150-CE-S AcuAMP AC 1-150 NC 0.2amp AcuAMP AC 1-150 NC 0.2amp - AcuAMP single-phase AC adjustable current switch, split core, 1.75-150A trip range adjustment with 4-turn potentiometer, N.C., 0.2A @ 240 VAC/DC output, LED indication, U … (read more)
$160.00
ACS200-AA-F AcuA 1.6,6-40,40-175 NO 1Amp AcuA 1.6,6-40,40-175 NO 1Amp - AcuAMP single-phase AC adjustable current switch, fixed core, 1-6, 6-40, or 40-175A trip ranges, N.O. 1.0A @ 240VAC output, UL 508 listed
$145.00
ACS200-CA-F AcuA 1.6,6-40,40-175 NC 1Amp AcuA 1.6,6-40,40-175 NC 1Amp - AcuAMP single-phase AC adjustable current switch, fixed core, 1-6, 6-40, or 40-175A input ranges, N.C. 1.0A @ 240VAC output, UL 508 listed
$145.00
ACS200-AD-F AcuA 1.6,6-40,40-175 NO 0.15A AcuA 1.6,6-40,40-175 NO 0.15A - AcuAMP single-phase AC adjustable current switch, fixed core, 1-6, 6-40, or 40-175A trip ranges, N.O. 0.15A @ 30VDC output, UL 508 listed
$145.00
ACS200-CD-F AcuA 1.6,6-40,40-175 NC 0.15A AcuA 1.6,6-40,40-175 NC 0.15A - AcuAMP single-phase AC adjustable current switch, fixed core, 1-6, 6-40, or 40-175A input ranges, N.C. 0.15A @ 30VDC output, UL 508 listed
$145.00
ACS200-AA-S AcuA 1.75-6,6-40,40-200NO 1Am AcuA 1.75-6,6-40,40-200NO 1Am - AcuAMP single-phase AC adjustable current switch, split core, 1.75-6, 6-40, or 40-200A trip ranges, N.O. 1.0A @ 240VAC output, UL 508 listed
$165.00
ACS200-CA-S AcuA 1.5-6,6-40,40-200NC 1Amp AcuA 1.5-6,6-40,40-200NC 1Amp - AcuAMP single-phase AC adjustable current switch, split core, 1.75-6, 6-40, or 40-200A input ranges, N.C. 1.0A @ 240VAC output, UL 508 listed
$165.00
ACS200-AD-S AcuA 1.75-6,6-40,40-200NO 0.1 AcuA 1.75-6,6-40,40-200NO 0.1 - AcuAMP single-phase AC adjustable current switch, split core, 1.75-6, 6-40, or 40-200A trip ranges, N.O. 0.15A @ 30VDC output, UL 508 listed
$165.00
ACS200-CD-S AcuA 1.5-6,5-40,40-200NC 0.15 AcuA 1.5-6,5-40,40-200NC 0.15 - AcuAMP single-phase AC adjustable current switch, split core, 1.75-6, 6-40, or 40-200A input ranges, N.C. 0.15A @ 30VDC output, UL 508 listed
$165.00
ACSX200-AE-F AcuA 1-12,12-55,55-175 NO AcuA 1-12,12-55,55-175 NO - AcuAMP single-phase AC adjustable current switch, fixed core, 1.5-12, 12-55, or 55-175A trip ranges, N.O. 0.15A @ 240 VAC/DC time adjustable output, UL 508 listed
$170.00
ACSX200-CE-F AcuA 1.5-12,12-55,50-200 NC AcuA 1.5-12,12-55,50-200 NC - AcuAMP single-phase AC adjustable current switch, fixed core, 1.5-12, 12-55, or 55-175A input ranges, N.C. 0.15A @ 240 VAC/DC time adjustable output, UL 508 listed
$170.00
ACSX200-AE-S AcuA 2-12,12-55,55-200 NO 0.1 AcuA 2-12,12-55,55-200 NO 0.1 - AcuAMP single-phase AC adjustable current switch, split core, 2-12, 12-55, or 55-200A trip ranges, N.O. 0.15A @ 240 VAC/DC time adjustable output, UL 508 listed
$190.00
ACSX200-CE-S AcuA 1.5-12,12-55,50-200 NC AcuA 1.5-12,12-55,50-200 NC - AcuAMP single-phase AC adjustable current switch, split core, 2-12, 12-55, or 55-200A input ranges, N.C. 0.15A @ 240 VAC/DC time adjustable output, UL 508 listed
$190.00
ACSX200-AA-S AcuA 2-12,12-55,55-200 NO 1A AcuA 2-12,12-55,55-200 NO 1A - AcuAMP single-phase AC adjustable current switch, split core, 2-12, 12-55, or 55-200A trip ranges, N.O. 1A @ 240VAC time adjustable output, UL 508 listed
$200.00
ACSX200-CA-S AcuA 1.5-12,12-55,50-200 NC 1 AcuA 1.5-12,12-55,50-200 NC 1 - AcuAMP single-phase AC adjustable current switch, split core, 2-12, 12-55, or 55-200A input ranges, N.C. 1A @ 240VAC time adjustable output, UL 508 listed
$200.00
DCS100-AE-24-F AcuAMP adjustable DC Switch AcuAMP adjustable DC Switch - AcuAMP adjustable DC current switch, fixed core, 5-15, 10-50, or 20-100A jumper-selectable trip ranges, 24 VAC/DC powered, N.O. 0.15A @ 240 VAC/DC output, UL 508 listed
$190.00
DCS100-1C-24-F AcuAMP adjustable DC switch AcuAMP adjustable DC switch - AcuAMP adjustable DC current switch, fixed core, 5-15, 10-50, or 20-100A jumper-selectable trip ranges, 24 VAC/DC powered, SPDT relay, 5A @ 240VAC or 30VDC output, UL 508 … (read more)
$200.00
ACL1 AcuAMP AC current indicator AcuAMP AC current indicator - AcuAMP AC current indicator, 0.5-100A indicating range, flashing red LED when AC current is present, UL 508 listed
$25.00
DRA-2 DinRail Adaptor for ACT Trans DinRail Adaptor for ACT Trans - DIN rail adapter for AcuAMP transducers and switches, pack of 2
$10.00
GFS30-M1A-24-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPST-N.O. relay output, manual reset, 24 VAC/DC powered, UL 1053 recognized
$420.00
GFS30-M1B-24-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPST-N.C. relay output, manual reset, 24 VAC/DC powered, UL 1053 recognized
$420.00
GFS30-D1C-24-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPDT normally de-energized relay output, automatic reset, 24 VAC/DC powered, UL 1053 r … (read more)
$290.00
GFS30-E1C-24-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPDT normally energized relay output, automatic reset, 24 VAC/DC powered, UL 1053 reco … (read more)
$310.00
GFS30-M1A-120A-F AcuAMP ground fault AcuAMP ground fault - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPST-N.O. relay output, manual reset, 120VAC powered, UL 1053 recognized
$420.00
GFS30-M1B-120A-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPST-N.C. relay output, manual reset, 120VAC powered, UL 1053 recognized
$420.00
GFS30-D1C-120A-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPDT normally de-energized relay output, automatic reset, 120VAC powered, UL 1053 reco … (read more)
$290.00
GFS30-E1C-120A-F AcuAMP ground fault sensor AcuAMP ground fault sensor - AcuAMP ground fault sensor, fixed core, jumper-selectable 5, 10, or 30 mA setpoint, SPDT normally energized relay output, automatic reset, 120VAC powered, UL 1053 recogni … (read more)
$310.00